IIP2 & DC Offsets
↳
IN the digital domain, zero crossings and ISI , as well as DC offset can be compromised.Loss of received signal strength with distortion, Overheating and damage to TX drivers Minder
↳
Worse is not working.
↳
30 ohms gives better power handling, 75 ohms gives low insertion loss, so 50 ohms is the trade off between the power handling and low insertion loss. It is globally accepted to use connector, cables and equipment for 50 ohms. Minder
↳
50 ohms performs better (lower loss than 75 ohms), one advantage of 75 ohms is size (cable and connectors are smaller than 50 ohms) Minder
↳
Please disregard prior answer, best insertion loss case is at 75 ohms, 50 ohms provides the best compromise between low loss and power handling as mentioned above. Minder
↳
1.) First of all mobile+SIM should be detected by mobile station. 2.) Then it passes the signal to BTS of the area, (which is occured in BSS). 3.) Then it passes to the neareast MSC by this it is connected to HLR,VLR,AUC & OMC, (which is occur in NSS). 4.) from this it is connected to PSTN,ISDN,DATA NETWORK(this all is occur in public network) Minder
↳
Kindly refer notes from any book, call flow cant be explained in this block.
↳
The magnitude of gamma=1/3, but you can't tell the phase. can be any point on the circle with a gamma=1/3 radius. Minder
↳
Gamma=(VSWR-1)/VSWR+1, so 0.333 is the reflection coefficient for VSWR=2
↳
.3333333
↳
Think out loud, it was more of a general discussion than a question-answer session. The interviewer was very helpful too. Minder
↳
Hi, DId they inform about you being rejected? When did you interview happened? It will be of great help if you can answer these!! :) Minder
↳
Hello sir, can you tell me how many days it took for a onsite interview after your phone process, I already had a interview with software team and waiting for results. Minder
↳
How soon did they get back to you about the result of onsite?
↳
for me it was about a month because there was christmas holiday break. otherwise it should be max 2 weeks. Minder
↳
Okay Thank you
↳
Assuming this is a "front end" of a receiver, the signal would be filtered and then pass through a LNA (Low Noise Amplifier). Minder
↳
Go to a really cold place to bring the surrounding noise down (near 0Kelvin ideally). Noise would only come from sky noise which is usually like 35Kelvin. Minder
↳
This might have been your "trick" question. This signal wouldnt be detectable. Even if you reciever is completely ideal with a NF of 0 and your signal of interest is in a 1Hz bandwidth, and your recieved signal is noiseless, your signal to noise ratio will be zero. SNR = P - 10logKTB SNR = -174dbm - (-174dbm/hz + 10log(1hz)) SNR = 0 Minder
↳
I & my team member try to find the solution of every problem........and give the solution which is appropriate ans of solution Minder
↳
I'm not a manager, I couldn't answer that positively, I had to improvise
↳
used to point a particular address in the memory
↳
- use to point a memory address - use to pass by reference- - in C used to initialize a character string Minder
↳
Just wondering if you still remember?
↳
Avoiding overshooting
↳
We can give mechanical tilt at sector which overshot and also power reducec at BTS. Minder